MegaGen’s AnyRidge® implants are designed to provide effective, less invasive, and aesthetically superior dental solutions. They are particularly suitable for immediate placement, immediate loading, and the use of short implants.
Whether you’re seeking a minimally invasive solution or a faster treatment timeline, AnyRidge implants offer unparalleled reliability and functionality. In this blog post, we’ll explore the unique features, clinical advantages, and why this advanced implant system is a preferred choice for patients and professionals alike.
What Are The Key Features of AnyRidge® Implants?
The key features of AnyRidge® Implants are;
- KnifeThread® Design: This innovative thread design allows for excellent initial stability across all bone densities (D1-D4) and ridge structures. Utilizing a standard core with varying thread depths preserves crestal bone and reduces overall bone loss.
- Xpeed® Surface Treatment: A unique hydro-thermal incorporation of calcium ions activates osteoblasts, accelerating osseointegration essential for secondary stability. This treatment also ensures the absence of acid residue, as indicated by its blue coloration. According to a study published in the Journal of Clinical Oral Investigation in 2017, the mean BIC% (bone-to-implant-contact) was %39.7 in the Xpeed® Implants, while it was %21.2 in the machined implants. This significant difference shows that The Xpeed® surface increases the peri-implant and osseous healing properties when compared with the machined surface.
- Double Offset® Structure: This design maximizes cortical bone preservation around implants, leading to better peri-marginal tissues and a more aesthetically pleasing gingival line.
- Biologic S-line: This feature incorporates a thread-less collar on the fixture and an S-line cuff design on the prosthetics, ensuring a better peri-implant biotype and emergence profile.
This video provides an in-depth look at the innovative features of the MegaGen AnyRidge® Implant System. It highlights the system’s unique design elements, such as the KnifeThread® design and Xpeed® surface treatment, which contribute to exceptional initial stability and rapid osseointegration.
Download the MegaGen AnyRidge® Product Catalog
What Are The Clinical Advantages of MegaGen AnyRidge®?
The clinical advantages of MegaGen AnyRidge® Implants are;
Immediate Loading Possibilities
Thanks to their exceptional initial stability, AnyRidge implants are ideal for immediate placement and loading, significantly reducing patients’ treatment time. Clinical studies1 published in reputable journals such as the European Journal of Oral Implantology and the Journal of Dental Research have demonstrated the success of immediate functional loading with AnyRidge implants. At 1 year, the survival rate was 97.7%, with minimal marginal bone loss of 0.32 mm and low complication rates. By the 4-year follow-up, the survival rate remained high at 97.6%, with an overall marginal bone loss of 0.38 mm. These results confirm that AnyRidge implants provide reliable outcomes for immediate loading protocols, ensuring long-term stability, minimal marginal bone loss, and patient satisfaction.
Adaptability to All Bone Conditions
Whether dealing with soft or hard bone, the AnyRidge system offers customizable drilling protocols to suit the specific bone quality and achieve desired stability.
Minimized Invasive Procedures
The ability to place wider fixtures in narrow crests minimizes the invasiveness of surgeries, enhancing patient comfort and reducing recovery times.
Read More: Minimal Invasive Dentistry
Proven Long-Term Success
Studies have shown that AnyRidge implants maintain high survival rates, even in challenging scenarios such as second molar replacements.
Why Choose Megagen AnyRidge® Implants?
The Megagen AnyRidge Implant System has redefined the standards of implantology by focusing on:
- Efficiency: Simplified surgical protocols reduce chair time for clinicians.
- Aesthetics: Advanced designs ensure natural-looking results.
- Patient Satisfaction: Painless and rapid treatments lead to stronger, more functional teeth
- Exceptional Stability for Immediate Loading: AnyRidge implants achieve high Implant Stability Quotient* (ISQ) values (≥ 60) and insertion torque (IT ≥ 45 N/cm), which are critical benchmarks for immediate loading protocols. This indicates rapid osseointegration and strong secondary stability, ensuring long-term success and reliability even in challenging cases.
* The Implant Stability Quotient (ISQ) is a critical metric for assessing the stability of dental implants during both primary and secondary stages. Measured using resonance frequency analysis, ISQ values range from 1 to 100, with higher values indicating greater stability.
This figure shows ISQ values for AnyRidge vs Conventional Implant.
Unlike other implant systems, the ISQ values for AnyRidge implants not only remain stable but often increase over time. This ensures rapid osseointegration and effective secondary stability, allowing for complete final prosthetics in 4 weeks, significantly reducing treatment time while maintaining excellent outcomes.
MegaGen AnyRidge® Implant Prices in Turkey
The price range for MegaGen AnyRidge® implants in Turkey is approximately £400 to £600 per implant. The average price is around £500, depending on the dental clinic, the specifics of the treatment, and any additional procedures required.
It’s recommended to consult directly with your chosen dental clinic for a personalized treatment plan and detailed pricing.
Where Can You Get MegaGen AnyRidge® Implants in Turkey?
Turkey has become a leading destination for high-quality dental care at competitive prices, making it an excellent choice for those seeking MegaGen AnyRidge® implants. At Maltepe Dental Clinic, we specialize in advanced implantology procedures using cutting-edge systems like AnyRidge.
Our experienced dental professionals ensure personalized treatment plans, minimal discomfort, and long-lasting results. With a commitment to patient satisfaction and the latest in dental technology, Maltepe Dental Clinic is your trusted partner for achieving a confident, healthy smile.
Contact Maltepe Dental Clinic today for more information on AnyRidge implants or to schedule a consultation. Let us help you achieve a confident, healthy smile!
SOURCES:
- – Luongo G., Lenzi C., Raes E., Eccrlente T., Ormsiani M., Margone C. ”Immediate functional loading of single implants: a 1-year interim report of a 5-year prospective multicenter study”, European Journal of Oral Implantology 2014; 7, 187-1 99
– Mangano C., Roes F., Lenti C., Eccellente T., Ortalani M., Luongo G., Mangano F. ”Immediate functional loading of Anyridige single implants: a 2-year prospective multicenter study”, The International Journal of Periodontics & Restorative Dentistry 2017, 37; 69-78
– Roes F., Ecceflente T., Lenai C., Ortolani M., Luonga G., Margane C., Mangano F. ”Immediate functional loading of single implants: a multicenter study with 4 years of follow-up”, Journal of Dental Research, Dental Clinics, Dental Prospects 2018, 1 2: 26-37 ↩︎